CONTROL OF NOx & OTHER EMISSIONS FROM POWER GENERATING PLANTS
WITH KOMAX STATIC MIXER TECHNOLOGY
|
Several competing systems
are available to reduce emissions in the exhaust gases of power
generating systems. Most of these depend on the introduction of
neutralizing additives to the exit stack of the plant. Highly efficient
mixing and contacting of the additive to the exit gases is a strict
requirement of these processes. Generally speaking, only a very small
pressure drop through the mixing system is allowed.
KOMAX Systems now
offers an additive injection and static mixer system
for these applications based on the most up to date technology and
design techniques. A good example of the technology involves a coal
fired generating plant in the United States. Here, the stack is about
100 meters tall and 4 meters in cross section. Ammonia is introduced to
the stack to neutralize nitrous oxide emissions. Good mixing and rapid
additive contacting is essential across the entire 20 meter width of the
stack. The Komax design was first modeled on 1:12 scale to test
performance. The pressure drop allowed was less than 0.02 bar or 0.7
inches of water with a gas flow rate of over 4 million pounds per hour.
In addition to providing
controlled and rapid contacting, the unique Komax design approach
improves the uniformity of gas temperature and flow distribution across
the entire stack width. This is vital to obtaining high efficiency
and consistent performance from down stream catalytic
beds. The structure of Komax design is modular, and the modules can be
arranged in many configurations reducing costs and
simplifying installation
KOMAX LARGE GAS
MIXER/SCRUBBERS
for DeNOx Application
|
I.
Customer: ORLANDO FLORIDA UTILITIES,
Stanton Coal Fired Power Plant.
Contractor: NOELL, INC- Herndon, VA
Plant Units 5 & 6
Application: To mix Vaporized Ammonia into Flue Gas
prior to the Catalyst
Bed in an SCR to reduce Nitrous Oxide.
Flow Rates: 927,800 SCFM
Reactor Duct and Komax Static Mixer Dimension: (W)
13 ft x (L) 58 ft x (H) 14 ft.
Number of Komax static mixers installed: 2 units
modular design assembled on site.
Date: May 1994
II.
Customer: ENEL - VADO LIGURE POWER Italy,
Plant Units 3 & 4
Contractor: TERMOKIMIK CORPORATION, Milan
Italy
Application: To mix Vaporized Ammonia into Flue Gas
prior to the Catalyst
Bed in an SCR to reduce Nitrous Oxide.
Flow Rates: 279,078 SCFM
Reactor Duct Dimension: (W) 2300 mm x (L) 8000 mm
Number of Komax Static Mixers Installed. 4 units
(Total)
Date: October 1998