The term "high
efficiency" flow conditioner has become
familiar in the industry over the past few
years. Komax has developed a significant
improvement to that technology in the Komax
Optimized Flow Conditioner.
By integrating a Komax
Triple Action Static Mixer with a standard
perforated plate conditioner, a new level of
robust flow conditioning has been achieved.
THE PROBLEM
Pipeline flows have a
parabolic velocity profile after long distance
undisturbed straight pipe runs.
Unfortunately meters cannot always be placed
in such a location due to installation
limitations. As space constraints place
elbows and flow disturbances close to meter
installations, flow conditioners become
critical to accurate metering
performance. Many different styles of
conditioners have been developed. Until
now, they all require significant straight
pipe lengths both upstream and prior to the
meter to offset their limitations.
KOMAX SOLUTION
Over the past 35 years,
Komax Systems has established a reputation for
partnering with industry to develop innovative
solutions. Our Triple Action adaptation
coined the CT (Custody Transfer) Mixer has
become the industry standard for conditioning
flows in preparation for water cut analysis.
Komax Systems was asked by
a major pipeline company to provide a more
effective solution to their numerous flow
conditioning applications. By installing
a specially adapted version of our famous
Triple Action Mixer immediately upstream of a
standard perforated plate flow conditioner,
significant improvements were realized.
No upstream straight pipe lengths are required
which eases constraints on pipe
installations. Only three pipe diameters
are required downstream to the meter
position. The Komax OFC can be mounted
immediately after an upstream elbow. The
Triple Action Mixer disassembles all the
improper flow characteristics and delivers
plug flow. This plug flow is delivered
to the perforated plate which then creates a
pseudo-developed parabolic profile.
Field testing of the KOFC
showed an 80% reduction in meter factor for an
ultrasonic flow meter.
Komax Optimized Flow
Conditioners can be economically built from 1
½" to 48" and are
configured as pipe spool assemblies or as pipe
inserts.